Product classification
Related Products
Communication cable for ships with rated voltage of 300V
Classification:
Summary:
- Product Description
- Parameter
-
1. Product executive standard
GJB 1916-94, enterprise standard.
2. Product application scope
Shipboard communication cable is mainly used in various shipboard and shipboard telecommunications, electronic computers, information processing equipment in the signal and control system.
3. Product use characteristics
3.1. Rated voltage: 300V.
3.2. The maximum allowable working temperature of conductor is 90 ℃, and the maximum temperature of conductor in case of short circuit (the short circuit time shall not exceed 5S) is 250 ℃.
3.3. Minimum bending radius of cable installation: 6D.
3.4. Ambient temperature of cable installation: - Ge; 0 ℃; ambient temperature of cable use: - 15 ℃ ~ 70 ℃.
3.5 power frequency withstand voltage of cable: 1.5kv/5min, no breakdown.
4. Main cable technology < span style = "font size: 12pt;" > index < / span >
4.1. Conductor structure: tinned copper wire, conforming to GJB 1916-94 Table 1-1 conductor.
4.2. Insulating material: ethylene propylene ternary.
4.3. Core identification: white and blue insulation digital code.
4.4. Armor: tinned copper wire.
4.5. Sheath: low smoke halogen-free crosslinked polyolefin.
-
Model Voltage Specifications Reference outer diameter mm Reference weight kg / km JHEP85/SC 300V 1×2×0.35 9.3 136 JHEP85/SC 300V 2×2×0.35 13.5 234 JHEP85/SC 300V 3×2×0.35 14.4 280 JHEP85/SC 300V 4×2×0.35 15.6 327 JHEP85/SC 300V 5×2×0.35 16.8 376 JHEP85/SC 300V 7×2×0.35 18.4 464 JHEP85/SC 300V 10×2×0.35 23.3 649 JHEP85/SC 300V 12×2×0.35 24.0 717 JHEP85/SC 300V 14×2×0.35 25.3 807 JHEP85/SC 300V 16×2×0.35 26.6 887 JHEP85/SC 300V 19×2×0.35 28.2 1010 JHEP85/SC 300V 24×2×0.35 32.8 1253 JHEP85/SC 300V 27×2×0.35 33.7 1368 JHEP85/SC 300V 30×2×0.35 34.9 1474 JHEP85/SC 300V 33×2×0.35 36.4 1603 JHEP85/SC 300V 37×2×0.35 37.7 1742 JHEP85/SC 300V 44×2×0.35 42.6 2075 JHEP85/SC 300V 48×2×0.35 43.3 2201 JHEP85/SC 300V 1×2×0.5 9.7 148 JHEP85/SC 300V 2×2×0.5 14.4 263 JHEP85/SC 300V 3×2×0.5 15.1 308 JHEP85/SC 300V 4×2×0.5 16.3 362 JHEP85/SC 300V 5×2×0.5 17.9 428 JHEP85/SC 300V 7×2×0.5 19.4 519 JHEP85/SC 300V 10×2×0.5 24.6 728 JHEP85/SC 300V 12×2×0.5 25.5 821 JHEP85/SC 300V 14×2×0.5 26.8 911 JHEP85/SC 300V 16×2×0.5 28.4 1018 JHEP85/SC 300V 19×2×0.5 29.8 1145 JHEP85/SC 300V 24×2×0.5 35.0 1442 JHEP85/SC 300V 27×2×0.5 35.7 1556 JHEP85/SC 300V 30×2×0.5 37.2 1701 JHEP85/SC 300V 33×2×0.5 38.6 1829 JHEP85/SC 300V 37×2×0.5 40.2 2013 JHEP85/SC 300V 44×2×0.5 45.4 2397 JHEP85/SC 300V 48×2×0.5 46.2 2546 JHEP85/SC 300V 1×2×0.75 10.1 159 JHEP85/SC 300V 2×2×0.75 15.0 286 JHEP85/SC 300V 3×2×0.75 15.8 339 JHEP85/SC 300V 4×2×0.75 17.4 410 JHEP85/SC 300V 5×2×0.75 18.8 474 JHEP85/SC 300V 7×2×0.75 20.6 590 JHEP85/SC 300V 10×2×0.75 26.1 828 JHEP85/SC 300V 12×2×0.75 26.9 921 JHEP85/SC 300V 14×2×0.75 28.4 1040 JHEP85/SC 300V 16×2×0.75 29.9 1147 JHEP85/SC 300V 19×2×0.75 31.7 1311 JHEP85/SC 300V 24×2×0.75 37.2 1650 JHEP85/SC 300V 27×2×0.75 38.0 1784 JHEP85/SC 300V 30×2×0.75 39.5 1951 JHEP85/SC 300V 33×2×0.75 41.0 2100 JHEP85/SC 300V 37×2×0.75 42.7 2313 JHEP85/SC 300V 44×2×0.75 48.3 2754 JHEP85/SC 300V 48×2×0.75 49.0 2929 JHEP85/SC 300V 1×2×1 10.4 172 JHEP85/SC 300V 2×2×1 15.7 311 JHEP85/SC 300V 3×2×1 16.5 371 JHEP85/SC 300V 4×2×1 18.2 451 JHEP85/SC 300V 5×2×1 19.9 535 JHEP85/SC 300V 7×2×1 21.5 656 JHEP85/SC 300V 10×2×1 27.4 921 JHEP85/SC 300V 12×2×1 28.5 1044 JHEP85/SC 300V 14×2×1 29.9 1164 JHEP85/SC 300V 16×2×1 31.7 1304 JHEP85/SC 300V 19×2×1 33.3 1475 JHEP85/SC 300V 24×2×1 39.4 1877 JHEP85/SC 300V 27×2×1 40.2 2034 JHEP85/SC 300V 30×2×1 41.8 2225 JHEP85/SC 300V 33×2×1 43.4 2398 JHEP85/SC 300V 37×2×1 45.2 2643 JHEP85/SC 300V 44×2×1 51.1 3144 JHEP85/SC 300V 48×2×1 51.9 3348 JHEP85/SC 300V 1×2×1.5 11.4 202 JHEP85/SC 300V 2×2×1.5 17.6 380 JHEP85/SC 300V 3×2×1.5 18.6 458 JHEP85/SC 300V 4×2×1.5 20.4 559 JHEP85/SC 300V 5×2×1.5 22.2 653 JHEP85/SC 300V 7×2×1.5 24.3 823 JHEP85/SC 300V 10×2×1.5 31.3 1174 JHEP85/SC 300V 12×2×1.5 32.2 1316 JHEP85/SC 300V 14×2×1.5 34.1 1490 JHEP85/SC 300V 16×2×1.5 35.9 1650 JHEP85/SC 300V 19×2×1.5 38.0 1894 JHEP85/SC 300V 24×2×1.5 44.9 2407 JHEP85/SC 300V 27×2×1.5 45.9 2613 JHEP85/SC 300V 30×2×1.5 47.7 2861 JHEP85/SC 300V 33×2×1.5 49.5 3087 JHEP85/SC 300V 37×2×1.5 51.6 3405 JHEP85/SC 300V 44×2×1.5 58.6 4080 JHEP85/SC 300V 48×2×1.5 59.5 4351 JHEP85/SC 300V 1×2×2.5 12.6 250 JHEP85/SC 300V 2×2×2.5 19.3 461 JHEP85/SC 300V 3×2×2.5 20.7 577 JHEP85/SC 300V 4×2×2.5 22.8 710 JHEP85/SC 300V 5×2×2.5 24.8 834 JHEP85/SC 300V 7×2×2.5 27.2 1061 JHEP85/SC 300V 10×2×2.5 35.0 1513 JHEP85/SC 300V 12×2×2.5 36.3 1729 JHEP85/SC 300V 14×2×2.5 38.1 1941 JHEP85/SC 300V 16×2×2.5 40.4 2179 JHEP85/SC 300V 19×2×2.5 42.8 2509 JHEP85/SC 300V 24×2×2.5 50.6 3183 JHEP85/SC 300V 27×2×2.5 51.7 3468 JHEP85/SC 300V 30×2×2.5 53.8 3801 JHEP85/SC 300V 33×2×2.5 56.0 4141 JHEP85/SC 300V 37×2×2.5 58.4 4573 JHEP85/SC 300V 44×2×2.5 66.0 5432 JHEP85/SC 300V 48×2×2.5 67.3 5844
Key words:
Communication cable for ships with rated voltage of 300V
Product inquiry
Filling in your phone and E-mail information will help us to get in touch with you in time and solve your problems as soon as possible.
Jiangsu Zhongmei Cable Co., Ltd.
National Service Hotline:0510-87201409
Company fax: 0510-87219001
Enterprise E-mail:web@jszmkl.com
Company address: Industrial Zone C, Guanlin Town, Yixing City, Jiangsu Province
Focus on us

Visit mobile official website