Rated voltage 150 / 250V marine communication cable


Summary:

Marine communication cable can be used for signal transmission and control system in telecommunication, electronic computer and information processing equipment. It is also applicable to metallurgical, chemical, electric and other industrial and mining enterprises.
  • Product Description
  • Parameter
  • 1. Product executive standard

    IEC 60092-350、IEC 60092-376。

    2. Product application scope

    Marine communication cable can be used for signal transmission and control system in telecommunication, electronic computer and information processing equipment. It is also applicable to metallurgical, chemical, electric and other industrial and mining enterprises.

    3. Product use characteristics

    3.1. Rated voltage: 150 / 250V.

    3.2. The maximum allowable working temperature of conductor is 90 ℃, and the maximum temperature of conductor in case of short circuit (the short circuit time shall not exceed 5S) is 250 ℃.

    3.3. Minimum bending radius of cable installation: 6D.

    3.4. Ambient temperature of cable installation: - Ge; 0 ℃; ambient temperature of cable use: - 15 ℃ ~ 70 ℃.

    3.5 power frequency withstand voltage of cable: 1.5kv/5min, no breakdown.

    4. Main technical indexes of cable

    4.1. Conductor structure: tinned copper wire, conforming to the second type of stranded conductor in GB / T 3956.

    4.2. Fire resistance: mica tape.

    4.3. Insulating material: cross linked polyethylene, in accordance with the relevant requirements of IEC 60092-360.

    4.4. Core identification: white and blue insulation printing black digital code.

    4.5. Split screen: tinned copper wire weaving.

    4.6. Inner sheath: low smoke halogen-free crosslinked polyolefin, meeting the relevant requirements of IEC 60092-360.

    4.7. Armor: tinned copper wire braid.

    4.8. Sheath: low smoke halogen-free crosslinked polyolefin, in accordance with the relevant requirements of IEC 60092-360.

  • Model Voltage Specifications Reference outer diameter mm Reference weight kg / km
    CHJPJP85/NC 150/250V 1*2*0.5 11.4  165
    CHJPJP85/NC 150/250V 2*2*0.5 17.4  323
    CHJPJP85/NC 150/250V 3*2*0.5 18.4  373
    CHJPJP85/NC 150/250V 4*2*0.5 19.8  441
    CHJPJP85/NC 150/250V 5*2*0.5 21.8  514
    CHJPJP85/NC 150/250V 7*2*0.5 23.4  624
    CHJPJP85/NC 150/250V 10*2*0.5 29.6  866
    CHJPJP85/NC 150/250V 12*2*0.5 31.0  953
    CHJPJP85/NC 150/250V 14*2*0.5 32.4  1064
    CHJPJP85/NC 150/250V 16*2*0.5 34.2  1180
    CHJPJP85/NC 150/250V 19*2*0.5 36.0  1336
    CHJPJP85/NC 150/250V 24*2*0.5 42.4  1763
    CHJPJP85/NC 150/250V 27*2*0.5 43.4  1889
    CHJPJP85/NC 150/250V 30*2*0.5 45.0  2045
    CHJPJP85/NC 150/250V 33*2*0.5 46.8  2210
    CHJPJP85/NC 150/250V 37*2*0.5 48.4  2414
    CHJPJP85/NC 150/250V 44*2*0.5 54.8  2865
    CHJPJP85/NC 150/250V 48*2*0.5 56.0  3055
    CHJPJP85/NC 150/250V 1*2*0.75 12.4  193
    CHJPJP85/NC 150/250V 2*2*0.75 19.0  391
    CHJPJP85/NC 150/250V 3*2*0.75 20.0  465
    CHJPJP85/NC 150/250V 4*2*0.75 22.0  541
    CHJPJP85/NC 150/250V 5*2*0.75 23.7  642
    CHJPJP85/NC 150/250V 7*2*0.75 26.2  769
    CHJPJP85/NC 150/250V 10*2*0.75 33.1  1105
    CHJPJP85/NC 150/250V 12*2*0.75 34.2  1217
    CHJPJP85/NC 150/250V 14*2*0.75 36.4  1361
    CHJPJP85/NC 150/250V 16*2*0.75 38.4  1508
    CHJPJP85/NC 150/250V 19*2*0.75 40.6  1792
    CHJPJP85/NC 150/250V 24*2*0.75 47.3  2263
    CHJPJP85/NC 150/250V 27*2*0.75 48.5  2428
    CHJPJP85/NC 150/250V 30*2*0.75 50.3  2633
    CHJPJP85/NC 150/250V 33*2*0.75 52.2  2841
    CHJPJP85/NC 150/250V 37*2*0.75 54.4  3103
    CHJPJP85/NC 150/250V 44*2*0.75 61.6  3708
    CHJPJP85/NC 150/250V 48*2*0.75 62.7  3919
    CHJPJP85/NC 150/250V 1*2*1 13.4  219
    CHJPJP85/NC 150/250V 2*2*1 19.8  432
    CHJPJP85/NC 150/250V 3*2*1 20.8  504
    CHJPJP85/NC 150/250V 4*2*1 22.8  612
    CHJPJP85/NC 150/250V 5*2*1 25.1  701
    CHJPJP85/NC 150/250V 7*2*1 27.4  872
    CHJPJP85/NC 150/250V 10*2*1 34.7  1214
    CHJPJP85/NC 150/250V 12*2*1 36.3  1361
    CHJPJP85/NC 150/250V 14*2*1 38.2  1520
    CHJPJP85/NC 150/250V 16*2*1 40.5  1777
    CHJPJP85/NC 150/250V 19*2*1 42.4  2005
    CHJPJP85/NC 150/250V 24*2*1 49.9  2533
    CHJPJP85/NC 150/250V 27*2*1 50.9  2721
    CHJPJP85/NC 150/250V 30*2*1 53.2  2976
    CHJPJP85/NC 150/250V 33*2*1 55.4  3191
    CHJPJP85/NC 150/250V 37*2*1 57.6  3512
    CHJPJP85/NC 150/250V 44*2*1 64.8  4165
    CHJPJP85/NC 150/250V 48*2*1 65.8  4467
    CHJPJP85/NC 150/250V 1*2*1.5 14.4  279
    CHJPJP85/NC 150/250V 2*2*1.5 22.0  492
    CHJPJP85/NC 150/250V 3*2*1.5 23.1  604
    CHJPJP85/NC 150/250V 4*2*1.5 25.4  710
    CHJPJP85/NC 150/250V 5*2*1.5 27.9  845
    CHJPJP85/NC 150/250V 7*2*1.5 30.7  1041
    CHJPJP85/NC 150/250V 10*2*1.5 39.3  1469
    CHJPJP85/NC 150/250V 12*2*1.5 40.7  1737
    CHJPJP85/NC 150/250V 14*2*1.5 42.8  1942
    CHJPJP85/NC 150/250V 16*2*1.5 45.1  2153
    CHJPJP85/NC 150/250V 19*2*1.5 47.5  2459
    CHJPJP85/NC 150/250V 24*2*1.5 56.3  3077
    CHJPJP85/NC 150/250V 27*2*1.5 57.6  3366
    CHJPJP85/NC 150/250V 30*2*1.5 59.7  3656
    CHJPJP85/NC 150/250V 33*2*1.5 62.2  3949
    CHJPJP85/NC 150/250V 37*2*1.5 64.7  4321
    CHJPJP85/NC 150/250V 44*2*1.5 73.0  5188
    CHJPJP85/NC 150/250V 48*2*1.5 74.2  5498
    CHJPJP85/NC 150/250V 1*2*2.5 15.4  325
    CHJPJP85/NC 150/250V 2*2*2.5 23.4  606
    CHJPJP85/NC 150/250V 3*2*2.5 25.0  727
    CHJPJP85/NC 150/250V 4*2*2.5 27.6  891
    CHJPJP85/NC 150/250V 5*2*2.5 30.5  1047
    CHJPJP85/NC 150/250V 7*2*2.5 32.9  1320
    CHJPJP85/NC 150/250V 10*2*2.5 42.6  1978
    CHJPJP85/NC 150/250V 12*2*2.5 44.0  2200
    CHJPJP85/NC 150/250V 14*2*2.5 46.4  2490
    CHJPJP85/NC 150/250V 16*2*2.5 49.1  2768
    CHJPJP85/NC 150/250V 19*2*2.5 51.7  3172
    CHJPJP85/NC 150/250V 24*2*2.5 61.4  4024
    CHJPJP85/NC 150/250V 27*2*2.5 62.6  4346
    CHJPJP85/NC 150/250V 30*2*2.5 65.0  4757
    CHJPJP85/NC 150/250V 33*2*2.5 67.7  5148
    CHJPJP85/NC 150/250V 37*2*2.5 70.5  5671
    CHJPJP85/NC 150/250V 44*2*2.5 79.8  6754
    CHJPJP85/NC 150/250V 48*2*2.5 81.0  7213

Key words:

Rated voltage 150 / 250V marine communication cable

Product inquiry

Filling in your phone and E-mail information will help us to get in touch with you in time and solve your problems as soon as possible.

Jiangsu Zhongmei Cable Co., Ltd.

National Service Hotline:0510-87201409

Company fax: 0510-87219001

Enterprise E-mail:web@jszmkl.com

Company address: Industrial Zone C, Guanlin Town, Yixing City, Jiangsu Province

Focus on us

Visit mobile official website

Visit mobile official website

©2024 Jiangsu Zhongmei Cable Co., Ltd.

Business License