Build a centenary enterprise, Forge an international brand

Products

Cables for rail transit vehicles with A.C. rated voltage of 3KV and below


Summary:

It is applicable to cables used for power distribution system, control system and electrical devices of signal system of rail transit vehicles with rated voltage of 3KV and below.
  • Product Description
  • Parameter
  • 1. Product executive standard

    GB/T12528-2008。

    2. Product application scope

    It is applicable to cables used for power distribution system, control system and electrical devices of signal system of rail transit vehicles with rated voltage of 3KV and below.

    3. Product use characteristics

    3.1. Rated voltage: 500V, 750V, 1000V, 1500V, 3000V.

    3.2. Maximum allowable working temperature of Conductor:

    Maximum allowable working temperature of dceh / 3-100 series Conductor: 100 ℃.

    The maximum allowable working temperature of wdz-dcyj-125 series conductor is 125 ℃.

    The maximum allowable working temperature of wdz-dcyj / 2-125 series conductor is 125 ℃.

    The maximum allowable working temperature of wdz-dcyj / 3-125 series conductor is 125 ℃.

    3.3. The minimum bending radius of cable installation is 6 times of cable outer diameter.

    3.4. Normal applicable ambient temperature of cable:

    Dceh / 3-100 series cable normal use environment temperature: - 25 ℃ ~ + 100 ℃.

    Wdz-dcyj-125 series cable normal use environment temperature: - 40 ℃ ~ + 125 ℃.

    Wdz-dcyj / 2-125 series cable normal use environment temperature: - 40 ℃ ~ + 125 ℃.

    Wdz-dcyj / 3-125 series cable normal use environment temperature: - 40 ℃ ~ + 125 ℃.

    3.5 power frequency withstand voltage of cable: 500V voltage: 2.0kv/5min, no breakdown; 750V voltage: 3.5kv/5min, no breakdown; 1500V voltage: 6.0kv/5min, no breakdown

    3000V voltage: 12.0kv/5min, no breakdown.

    4. Main technical indexes of cable

    4.1. Conductor structure: in accordance with GB / T 3956 conductor regulations.

    4.2. Insulation material: dceh / 3-100: ethylene propylene rubber insulation, meeting the relevant requirements of GB / T 12528.

    Wdz-dcyj-125, wdz-dcyj / 2-125, wdz-dcyj / 3-125: 125 degree low smoke halogen-free irradiation crosslinked polyolefin insulation, meeting the relevant requirements of GB / T 12528.

    4.3. Sheath: dceh / 3-100: chlorosulfonated polyethylene rubber mixture, meeting the relevant requirements of GB / T 12528.

  • Model Voltage Specifications Reference OD Reference weight
    DCEH/3-100  750V 1x0.5  3.9 22
    1x0.75  4.1 26
    1x1  4.3 30
    1x1.5  4.5 35
    1x2.5  5.2 50
    1x4  5.7 66
    1x6  6.3 87
    1x10  8.2 149
    1x16  9.2 208
    1x25  11.3 316
    1x35  12.9 425
    1x50  15.1 597
    1x70  17.0 802
    1x95  19.8 1069
    1x120  21.2 1310
    1x150  24.8 1678
    1x185  26.6 2004
    1x240  31.0 2680
    1x300  33.3 3238
    DCEH/3-100  1500V 1x1  5.1 39
    1x1.5  5.3 45
    1x2.5  6.2 63
    1x4  6.7 81
    1x6  7.3 103
    1x10  9.0 165
    1x16  10.0 227
    1x25  12.1 338
    1x35  13.7 450
    1x50  15.9 626
    1x70  17.8 835
    1x95  20.6 1107
    1x120  22.0 1351
    1x150  25.4 1707
    1x185  27.2 2036
    1x240  31.8 2739
    1x300  34.1 3301
    DCEH/3-100  3000V 1x2.5  7.8 90
    1x4  8.3 109
    1x6  8.9 134
    1x10  10.6 201
    1x16  11.6 267
    1x25  13.7 386
    1x35  15.3 504
    1x50  18.1 711
    1x70  20.0 929
    1x95  22.8 1214
    1x120  24.2 1465
    1x150  27.4 1830
    1x185  29.2 2167
    1x240  33.8 2892
    1x300  36.1 3465
    WDZ-DCYJ-125       WDZ-DCYJ/2-125     WDZ-DCYJ/3-125 750V 1x0.5  2.6 12 
    1x0.75  2.8 15 
    1x1  3.0 18 
    1x1.5  3.2 23 
    1x2.5  3.7 33 
    1x4  4.2 47 
    1x6  4.8 68 
    1x10  6.9 127 
    1x16  7.9 184 
    1x25  9.2 268 
    1x35  10.8 368 
    1x50  12.6 518 
    1x70  14.9 717 
    1x95  16.9 945 
    1x120  18.7 1189 
    1x150  21.2 1476 
    1x185  23.0 1796 
    1x240  26.0 2388 
    1x300  28.3 2901 
    WDZ-DCYJ-125       WDZ-DCYJ/2-125     WDZ-DCYJ/3-125 1500V 1x0.75  3.7 21.4
    1x1  3.9 24.8
    1x1.5  4.1 30.3
    1x2.5  4.6 41.4
    1x4  5.1 56.6
    1x6  5.7 78.6
    1x10  7.3 134.1
    1x16  8.3 191.8
    1x25  9.6 277.1
    1x35  11.2 379.2
    1x50  13.0 530.9
    1x70  15.3 732.4
    1x95  17.8 980.6
    1x120  19.6 1228.0
    1x150  22.0 1519.9
    1x185  23.8 1843.1
    1x240  26.8 2441.1
    1x300  29.1 2958.9
    WDZ-DCYJ-125       WDZ-DCYJ/2-125     WDZ-DCYJ/3-125 3000V 1x0.75  4.1 25.4
    1x1  4.3 29.0
    1x1.5  4.5 34.8
    1x2.5  5.0 46.4
    1x4  5.5 62.0
    1x6  6.1 84.6
    1x10  7.7 141.7
    1x16  8.7 200.4
    1x25  10.0 287.1
    1x35  11.6 390.8
    1x50  13.9 558.2
    1x70  15.8 748.2
    1x95  18.2 998.8
    1x120  20.0 1248.1
    1x150  22.4 1542.4
    1x185  24.2 1867.4
    1x240  27.2 2468.5
    1x300  29.5 2988.6

Key words:

Cables for rail transit vehicles with A.C. rated voltage of 3KV and below

Product inquiry

Filling in your phone and E-mail information will help us to get in touch with you in time and solve your problems as soon as possible.

Jiangsu Zhongmei Cable Co., Ltd.

National Service Hotline:0510-87201409

Company fax: 0510-87219001

Enterprise E-mail:web@jszmkl.com

Company address: Industrial Zone C, Guanlin Town, Yixing City, Jiangsu Province

Focus on us

Visit mobile official website

Visit mobile official website

©2024 Jiangsu Zhongmei Cable Co., Ltd.

Business License