Product classification
Related Products
Mobile halogen-free low smoke rubber sheathed flexible cable for coal mine
Classification:
Summary:
- Product Description
- Parameter
-
1. Product executive standard
Enterprise standards.
2. Product application scope
Wd-my-0.38/0.66: it is applicable to the power connection of various underground mobile coal mining equipment with rated voltage of 0.38/0.66kv, and it is not applicable to the places with frequent winding and retraction.
Wd-myp-0.38/0.66: it is applicable to the power connection of various underground mobile coal mining equipment with rated voltage of 0.38/0.66kv, and it is not applicable to the places with frequent winding and retraction.
Wd-myp-0.66/1.14kv: suitable for power connection of various underground mobile mining equipment with rated voltage of 0.66/1.14kv, not suitable for frequent winding and retraction.
3. Product use characteristics
3.1. Rated voltage: 0.38/0.66kv, 0.66/1.14kv.
3.2. The maximum allowable working temperature of conductor is 90 ℃, and the maximum temperature of conductor in case of short circuit (the short circuit time shall not exceed 5S) is 250 ℃.
3.3. The minimum bending radius of cable is 6 times of cable diameter.
3.4. The normal applicable ambient temperature of the cable is - 25 ℃ ~ + 65 ℃..
3.5. The flame retardant performance of the cable shall meet the requirements of flame retardant performance in MT 818-2009.
3.6 power frequency withstand voltage of cable: 0.38/0.66kv voltage: 3.0kv/5min without breakdown, 0.66/1.14kv voltage: 3.7kv/5min without breakdown.
4. Main technical indexes of cable
4.1. Conductor structure: bare copper conductor, conforming to the 5th soft copper conductor in GB / T 3956.
4.2. Insulating material: the power wire core is made of ethylene propylene rubber as the base material. Its performance shall comply with the provisions of xj-30a type in GB / T 7594.8, and its tensile strength shall not be less than 6.5MPa.
4.3. Core identification: main core: red, white, blue, ground core: black.
4.4. Sheath: it shall comply with XH & mdash; 03A in GB / T 7594.7, and its tear strength shall not be less than 5N / mm, and shall also meet the performance requirements of low smoke halogen-free flame retardant mixture.
-
Model Voltage Specifications Reference OD Reference weight WD-MY 0.38/0.66KV 3×4+1×4 21.0 601 WD-MY 0.38/0.66KV 3×6+1×6 23.0 712 WD-MY 0.38/0.66KV 3×10+1×10 27.0 1105 WD-MY 0.38/0.66KV 3×16+1×10 29.5 1355 WD-MY 0.38/0.66KV 3×25+1×16 34.5 1932 WD-MY 0.38/0.66KV 3×35+1×16 37.5 2440 WD-MY 0.38/0.66KV 3×50+1×16 43.5 3206 WD-MY 0.38/0.66KV 3×50+1×25 43.5 3259 WD-MY 0.38/0.66KV 3×70+1×25 48.0 4110 WD-MY 0.38/0.66KV 3×70+1×35 48.0 4173 WD-MY 0.38/0.66KV 3×95+1×25 54.5 5362 WD-MY 0.38/0.66KV 3×95+1×35 54.5 5424 WD-MY 0.38/0.66KV 3×120+1×35 58.0 6351 WD-MY 0.38/0.66KV 3×120+1×50 58.0 6439 WD-MY 0.38/0.66KV 3×120+1×70 58.0 6560 WD-MY 0.38/0.66KV 3×150+1×50 64.5 7915 WD-MY 0.38/0.66KV 3*150+1×70 64.5 8035 WD-MY 0.38/0.66KV 3×185+1×50 68.5 9211 WD-MY 0.38/0.66KV 3×185+1×70 68.5 9330 WD-MYP 0.38/0.66KV 3×4+1×4 23.5 615 WD-MYP 0.38/0.66KV 3×6+1×6 25.5 726 WD-MYP 0.38/0.66KV 3×10+1×10 29.5 1117 WD-MYP 0.38/0.66KV 3×16+1×10 32.0 1369 WD-MYP 0.38/0.66KV 3×25+1×16 37.0 1943 WD-MYP 0.38/0.66KV 3×35+1×16 40.0 2453 WD-MYP 0.38/0.66KV 3×50+1×16 46.0 3215 WD-MYP 0.38/0.66KV 3×50+1×25 46.0 3268 WD-MYP 0.38/0.66KV 3×70+1×25 50.5 4120 WD-MYP 0.38/0.66KV 3×70+1×35 50.5 4277 WD-MYP 0.38/0.66KV 3×95+1×25 57.0 5366 WD-MYP 0.38/0.66KV 3×95+1×35 57.0 5429 WD-MYP 0.38/0.66KV 3×120+1×35 60.5 6356 WD-MYP 0.38/0.66KV 3×120+1×50 60.5 6444 WD-MYP 0.38/0.66KV 3×120+1×70 60.5 6523 WD-MYP 0.38/0.66KV 3×150+1×50 67.0 7913 WD-MYP 0.38/0.66KV 3*150+1×70 67.0 8032 WD-MYP 0.38/0.66KV 3×185+1×50 70.3 9209 WD-MYP 0.38/0.66KV 3×185+1×70 70.3 9327 WD-MYP 0.66/1.14KV 3×10+1×10 31.5 1251 WD-MYP 0.66/1.14KV 3×16+1×10 34.0 1513 WD-MYP 0.66/1.14KV 3×25+1×16 38.1 211 WD-MYP 0.66/1.14KV 3×35+1×16 42.0 2639 WD-MYP 0.66/1.14KV 3×50+1×16 48.0 3426 WD-MYP 0.66/1.14KV 3×50+1×25 48.0 3479 WD-MYP 0.66/1.14KV 3×70+1×25 52.5 4351 WD-MYP 0.66/1.14KV 3×70+1×35 52.5 4414 WD-MYP 0.66/1.14KV 3×95+1×25 59.0 5630 WD-MYP 0.66/1.14KV 3×95+1×35 59.0 5693 WD-MYP 0.66/1.14KV 3×120+1×35 62.5 6635 WD-MYP 0.66/1.14KV 3×120+1×50 62.5 6723 WD-MYP 0.66/1.14KV 3×150+1×50 68.0 8056 WD-MYP 0.66/1.14KV 3*150+1×70 68.0 8175 WD-MYP 0.66/1.14KV 3×185+1×50 72.0 9360 WD-MYP 0.66/1.14KV 3×185+1×70 72.0 9479
Key words:
Mobile halogen-free low smoke rubber sheathed flexible cable for coal mine
Product inquiry
Filling in your phone and E-mail information will help us to get in touch with you in time and solve your problems as soon as possible.