Product classification
Related Products
Reinforced rubber sheathed flexible cable for metal shield monitoring of Shearer
Classification:
Summary:
- Product Description
- Parameter
-
1. Product executive standard
Enterprise standards.
2. Product application scope
Mcptjb-0.66/1.14 and mcptjr-0.66/1.14 are applicable to the power connection of shearer and similar equipment with rated voltage of 0.66/1.14kv and below, and the cable can be directly dragged for use.
Mcptjb-1.9/3.3 and mcptjr-1.9/3.3 are applicable to the power connection of shearer and similar equipment with rated voltage of 1.9/3.3kv and below, and the cable can be directly dragged for use.
3. Product use characteristics
3.1. Rated voltage: 0.66/1.14kv, 1.9/3.3kv.
3.2. The maximum allowable working temperature of conductor is 90 ℃, and the maximum temperature of conductor in case of short circuit (the short circuit time shall not exceed 5S) is 250 ℃.
3.3. The minimum bending radius of cable is 6 times of cable diameter.
3.4. The normal applicable ambient temperature of the cable is - 25 ℃ ~ + 65 ℃.
3.5. The flame retardant performance of the cable shall meet the requirements of flame retardant performance in MT 818-2009.
3.6 power frequency withstand voltage of cable: 0.66/1.14kv voltage: 3.7kv/5min without breakdown, 1.9/3kv voltage: 6.8kv/5min without breakdown.
4. Main technical indexes of cable
4.1. Conductor structure: Tinned Soft Copper conductor, in accordance with GB / T 3956, type 5 soft copper conductor.
4.2. Insulating material: the power wire core, control wire core and monitoring wire core are made of ethylene propylene rubber as the base material, which complies with the requirements of xj-30a type in GB / T 7594.8-1987, but the tensile strength shall not be less than 6.5MPa.
4.3. Core identification: main core: code or color yarn identification; control line: white insulation plus black code.
4.4. Outer sheath: the sheath rubber or other materials with similar performance using neoprene as the base material shall meet the requirements of xh-03a in GB / T 7594.7, and the tear strength shall not be less than 5.0n/mm.
-
Model Voltage Specifications Reference OD MCPTJR 0.66/1.14KV 3*10+1*10+3*1.5+3*1.5 33.5 MCPTJR 0.66/1.14KV 3*16+1*16+3*1.5+3*1.5 36.5 MCPTJR 0.66/1.14KV 3*25+1*16+3*1.5+3*1.5 37.5 MCPTJR 0.66/1.14KV 3*35+1*16+3*1.5+3*1.5 40.5 MCPTJR 0.66/1.14KV 3*50+1*25+3*1.5+3*1.5 45.0 MCPTJR 0.66/1.14KV 3*70+1*35+3*1.5+3*1.5 50.0 MCPTJR 0.66/1.14KV 3*95+1*50+3*1.5+3*1.5 55.5 MCPTJR 0.66/1.14KV 3*120+1*50+3*1.5+3*1.5 59.0 MCPTJR 0.66/1.14KV 3*150+1*70+3*1.5+3*1.5 64.5 MCPTJR 0.66/1.14KV 3*185+1*95+3*1.5+3*1.5 69.0 MCPTJR 0.66/1.14KV 3*240+1*95+3*1.5+3*1.5 75.0 MCPTJB 0.66/1.14KV 3*10+1*10+3*1.5+3*1.5 36.5 MCPTJB 0.66/1.14KV 3*16+1*16+3*1.5+3*1.5 38.5 MCPTJB 0.66/1.14KV 3*25+1*16+3*1.5+3*1.5 40.5 MCPTJB 0.66/1.14KV 3*35+1*163*1.5+3*1.5 43.5 MCPTJB 0.66/1.14KV 3*50+1*25+3*1.5+3*1.5 48.0 MCPTJB 0.66/1.14KV 3*70+1*35+3*1.5+3*1.5 53.0 MCPTJB 0.66/1.14KV 3*95+1*50+3*1.5+3*1.5 58.5 MCPTJB 0.66/1.14KV 3*120+1*50+3*1.5+3*1.5 62.0 MCPTJB 0.66/1.14KV 3*150+1*70+3*1.5+3*1.5 67.5 MCPTJB 0.66/1.14KV 3*185+1*95+3*1.5+3*1.5 72.0 MCPTJB 0.66/1.14KV 3*240+1*95+3*1.5+3*1.5 78.0 MCPTJR 1.9/3.3KV 3*10+1*10+3*1.5+3*1.5 36.5 MCPTJR 1.9/3.3KV 3*16+1*16+3*1.5+3*1.5 39.0 MCPTJR 1.9/3.3KV 3*25+1*16+3*1.5+3*1.5 42.0 MCPTJR 1.9/3.3KV 3*35+1*163*1.5+3*1.5 46.0 MCPTJR 1.9/3.3KV 3*50+1*25+3*1.5+3*1.5 50.0 MCPTJR 1.9/3.3KV 3*70+1*35+3*1.5+3*1.5 53.5 MCPTJR 1.9/3.3KV 3*95+1*50+3*1.5+3*1.5 60.5 MCPTJR 1.9/3.3KV 3*120+1*50+3*1.5+3*1.5 63.5 MCPTJR 1.9/3.3KV 3*150+1*70+3*1.5+3*1.5 67.0 MCPTJR 1.9/3.3KV 3*185+1*95+3*1.5+3*1.5 72.0 MCPTJR 1.9/3.3KV 3*240+1*95+3*1.5+3*1.5 78.0 MCPTJB 1.9/3.3KV 3*10+1*10+3*1.5+3*1.5 39.5 MCPTJB 1.9/3.3KV 3*16+1*16+3*1.5+3*1.5 42.0 MCPTJB 1.9/3.3KV 3*25+1*16+3*1.5+3*1.5 45.0 MCPTJB 1.9/3.3KV 3*35+1*163*1.5+3*1.5 49.0 MCPTJB 1.9/3.3KV 3*50+1*25+3*1.5+3*1.5 53.0 MCPTJB 1.9/3.3KV 3*70+1*35+3*1.5+3*1.5 56.5 MCPTJB 1.9/3.3KV 3*95+1*50+3*1.5+3*1.5 63.5 MCPTJB 1.9/3.3KV 3*120+1*50+3*1.5+3*1.5 66.5 MCPTJB 1.9/3.3KV 3*150+1*70+3*1.5+3*1.5 70.0 MCPTJB 1.9/3.3KV 3*185+1*95+3*1.5+3*1.5 75.0 MCPTJB 1.9/3.3KV 3*240+1*95+3*1.5+3*1.5 81.0
Key words:
Reinforced rubber sheathed flexible cable for metal shield monitoring of Shearer
Product inquiry
Filling in your phone and E-mail information will help us to get in touch with you in time and solve your problems as soon as possible.
Jiangsu Zhongmei Cable Co., Ltd.
National Service Hotline:0510-87201409
Company fax: 0510-87219001
Enterprise E-mail:web@jszmkl.com
Company address: Industrial Zone C, Guanlin Town, Yixing City, Jiangsu Province
Focus on us
Visit mobile official website