1. Product executive standard
GJB 1916-94, enterprise standard.
2. Product application scope
Power cables for ships can be used for power, lighting and general control devices of various ships and offshore oil platforms.
3. Product use characteristics
3.1. Rated voltage: 0.6/1kv.
3.2. The maximum allowable working temperature of conductor is 90 ℃, and the maximum temperature of conductor in case of short circuit (the short circuit time shall not exceed 5S) is 250 ℃.
3.3. Minimum bending radius of cable installation: 6D.
3.4. Ambient temperature of cable installation: - Ge; 0 ℃; ambient temperature of cable use: - 15 ℃ ~ 70 ℃.
3.5 power frequency withstand voltage of cable: 3.5kv/5min, no breakdown.
4. Main technical indexes of cable
4.1. Conductor structure: tinned copper wire, conforming to GJB 1916-94 Table 1-1 conductor.
4.2. Insulation material: XLPE.
4.3. Core identification: white insulation black digital code.
4.4. Sheath: low smoke halogen-free crosslinked polyolefin.
-
Model Voltage Specifications Reference outer diameter mm Reference weight kg / km JYJPJ/SC 0.6/1kV 1×1.0 5.3 38 JYJPJ/SC 0.6/1kV 1×1.5 5.6 45 JYJPJ/SC 0.6/1kV 1×2.5 6.0 58 JYJPJ/SC 0.6/1kV 1×4.0 6.6 76 JYJPJ/SC 0.6/1kV 1×6.0 7.1 98 JYJPJ/SC 0.6/1kV 1×10 8.1 143 JYJPJ/SC 0.6/1kV 1×16 9.4 213 JYJPJ/SC 0.6/1kV 1×25 11.1 314 JYJPJ/SC 0.6/1kV 1×35 12.6 422 JYJPJ/SC 0.6/1kV 1×50 14.7 602 JYJPJ/SC 0.6/1kV 1×70 16.4 789 JYJPJ/SC 0.6/1kV 1×95 18.5 1046 JYJPJ/SC 0.6/1kV 1×120 20.6 1331 JYJPJ/SC 0.6/1kV 1×150 22.8 1627 JYJPJ/SC 0.6/1kV 1×185 24.8 1961 JYJPJ/SC 0.6/1kV 1×240 28.1 2548 JYJPJ/SC 0.6/1kV 1×300 31.0 3177 JYJPJ/SC 0.6/1kV 2×1.0 9.1 103 JYJPJ/SC 0.6/1kV 2×1.5 9.6 121 JYJPJ/SC 0.6/1kV 2×2.5 10.6 157 JYJPJ/SC 0.6/1kV 2×4.0 11.8 209 JYJPJ/SC 0.6/1kV 2×6.0 13.0 269 JYJPJ/SC 0.6/1kV 2×10 15.1 393 JYJPJ/SC 0.6/1kV 2×16 17.6 574 JYJPJ/SC 0.6/1kV 2×25 21.2 860 JYJPJ/SC 0.6/1kV 2×35 23.9 1137 JYJPJ/SC 0.6/1kV 2×50 28.1 1621 JYJPJ/SC 0.6/1kV 2×70 31.8 2133 JYJPJ/SC 0.6/1kV 2×95 35.6 2788 JYJPJ/SC 0.6/1kV 2×120 39.9 3548 JYJPJ/SC 0.6/1kV 3×1.0 9.3 111 JYJPJ/SC 0.6/1kV 3×1.5 9.8 133 JYJPJ/SC 0.6/1kV 3×2.5 10.9 179 JYJPJ/SC 0.6/1kV 3×4.0 12.2 243 JYJPJ/SC 0.6/1kV 3×6.0 13.4 320 JYJPJ/SC 0.6/1kV 3×10 15.7 480 JYJPJ/SC 0.6/1kV 3×16 18.4 712 JYJPJ/SC 0.6/1kV 3×25 22.3 1078 JYJPJ/SC 0.6/1kV 3×35 25.4 1453 JYJPJ/SC 0.6/1kV 3×50 29.6 2066 JYJPJ/SC 0.6/1kV 3×70 33.8 2753 JYJPJ/SC 0.6/1kV 3×95 37.9 3622 JYJPJ/SC 0.6/1kV 3×120 42.5 4619 JYJPJ/SC 0.6/1kV 3×150 47.0 5644 JYJPJ/SC 0.6/1kV 3×185 51.9 6874 JYJPJ/SC 0.6/1kV 4×1.0 10.0 133 JYJPJ/SC 0.6/1kV 4×1.5 10.7 160 JYJPJ/SC 0.6/1kV 4×2.5 12.1 225 JYJPJ/SC 0.6/1kV 4×4.0 13.3 299 JYJPJ/SC 0.6/1kV 4×6.0 14.9 405 JYJPJ/SC 0.6/1kV 4×10 17.4 610 JYJPJ/SC 0.6/1kV 4×16 20.4 908 JYJPJ/SC 0.6/1kV 4×25 24.8 1378 JYJPJ/SC 0.6/1kV 4×35 28.1 1858 JYJPJ/SC 0.6/1kV 4×50 32.9 2648 JYJPJ/SC 0.6/1kV 4×70 37.5 3531 JYJPJ/SC 0.6/1kV 4×95 42.3 4678 JYJPJ/SC 0.6/1kV 4×120 47.4 5964 JYJPJ/SC 0.6/1kV 4×150 52.4 7287 JYJPJ/SC 0.6/1kV 5×1 11.4 164 JYJPJ/SC 0.6/1kV 6×1 12.6 200 JYJPJ/SC 0.6/1kV 7×1 12.6 198 JYJPJ/SC 0.6/1kV 8×1 13.5 220 JYJPJ/SC 0.6/1kV 10×1 15.9 286 JYJPJ/SC 0.6/1kV 12×1 16.4 315 JYJPJ/SC 0.6/1kV 14×1 16.3 341 JYJPJ/SC 0.6/1kV 16×1 17.3 390 JYJPJ/SC 0.6/1kV 19×1 18.2 433 JYJPJ/SC 0.6/1kV 24×1 21.3 551 JYJPJ/SC 0.6/1kV 27×1 21.8 596 JYJPJ/SC 0.6/1kV 30×1 22.8 660 JYJPJ/SC 0.6/1kV 33×1 23.6 715 JYJPJ/SC 0.6/1kV 37×1 24.5 774 JYJPJ/SC 0.6/1kV 5×1.5 11.8 197 JYJPJ/SC 0.6/1kV 6×1.5 12.8 232 JYJPJ/SC 0.6/1kV 7×1.5 12.8 235 JYJPJ/SC 0.6/1kV 8×1.5 13.7 262 JYJPJ/SC 0.6/1kV 10×1.5 16.2 339 JYJPJ/SC 0.6/1kV 12×1.5 16.6 377 JYJPJ/SC 0.6/1kV 14×1.5 17.7 434 JYJPJ/SC 0.6/1kV 16×1.5 18.6 486 JYJPJ/SC 0.6/1kV 19×1.5 19.6 543 JYJPJ/SC 0.6/1kV 24×1.5 23.2 703 JYJPJ/SC 0.6/1kV 27×1.5 23.7 763 JYJPJ/SC 0.6/1kV 30×1.5 24.5 830 JYJPJ/SC 0.6/1kV 33×1.5 25.7 916 JYJPJ/SC 0.6/1kV 37×1.5 26.6 994 JYJPJ/SC 0.6/1kV 5×2.5 13.1 270 JYJPJ/SC 0.6/1kV 6×2.5 14.4 327 JYJPJ/SC 0.6/1kV 7×2.5 14.4 335 JYJPJ/SC 0.6/1kV 8×2.5 15.5 374 JYJPJ/SC 0.6/1kV 10×2.5 18.3 482 JYJPJ/SC 0.6/1kV 12×2.5 18.9 542 JYJPJ/SC 0.6/1kV 14×2.5 20.1 623 JYJPJ/SC 0.6/1kV 16×2.5 21.1 700 JYJPJ/SC 0.6/1kV 19×2.5 22.2 789 JYJPJ/SC 0.6/1kV 24×2.5 26.3 1016 JYJPJ/SC 0.6/1kV 27×2.5 26.9 1108 JYJPJ/SC 0.6/1kV 30×2.5 27.8 1210 JYJPJ/SC 0.6/1kV 33×2.5 29.1 1334 JYJPJ/SC 0.6/1kV 37×2.5 30.2 1454 JYJPJ/SC 0.6/1kV 5×4.0 14.7 369 JYJPJ/SC 0.6/1kV 6×4.0 16.0 438 JYJPJ/SC 0.6/1kV 7×4.0 16.0 454 JYJPJ/SC 0.6/1kV 8×4.0 17.5 518 JYJPJ/SC 0.6/1kV 10×4.0 20.6 665 JYJPJ/SC 0.6/1kV 12×4.0 21.2 753 JYJPJ/SC 0.6/1kV 14×4.0 22.3 855 JYJPJ/SC 0.6/1kV 16×4.0 23.7 977 JYJPJ/SC 0.6/1kV 19×4.0 25.0 1107 JYJPJ/SC 0.6/1kV 24×4.0 29.6 1420 JYJPJ/SC 0.6/1kV 27×4.0 30.3 1555 JYJPJ/SC 0.6/1kV 30×4.0 31.6 1720 JYJPJ/SC 0.6/1kV 33×4.0 32.8 1875 JYJPJ/SC 0.6/1kV 37×4.0 34.3 2070
Key words:
Power cable for ships with rated voltage of 0.6/1kv
Product inquiry
Filling in your phone and E-mail information will help us to get in touch with you in time and solve your problems as soon as possible.
Jiangsu Zhongmei Cable Co., Ltd.
National Service Hotline:0510-87201409
Company fax: 0510-87219001
Enterprise E-mail:web@jszmkl.com
Company address:No. 6, Shuguang Road, Guanlin Town, Yixing City, Jiangsu Province
Focus on us
Visit mobile official website