Product classification
Related Products
Power cable for ships with rated voltage of 0.6/1kv
Classification:
Summary:
- Product Description
- Parameter
-

1. Product executive standard
GJB 1916-94, enterprise standard.
2. Product application scope
Power cables for ships can be used for power, lighting and general control devices of various ships and offshore oil platforms.
3. Product use characteristics
3.1. Rated voltage: 0.6/1kv.
3.2. The maximum allowable working temperature of conductor is 90 ℃, and the maximum temperature of conductor in case of short circuit (the short circuit time shall not exceed 5S) is 250 ℃.
3.3. Minimum bending radius of cable installation: 6D.
3.4. Ambient temperature of cable installation: - Ge; 0 ℃; ambient temperature of cable use: - 15 ℃ ~ 70 ℃.
3.5 power frequency withstand voltage of cable: 3.5kv/5min, no breakdown.
4. Main technical indexes of cable
4.1. Conductor structure: tinned copper wire, conforming to GJB 1916-94 Table 1-1 conductor.
4.2. Insulation material: XLPE.
4.3. Core identification: white insulation black digital code.
4.4. Inner sheath: low smoke halogen-free crosslinked polyolefin.
4.5. Armor: tinned copper wire braid.
4.6. Sheath: low smoke halogen-free crosslinked polyolefin.
-
Model Voltage Specifications Reference outer diameter mm Reference weight kg / km JYJPJ85/SC 0.6/1kV 1×1.0 8.4 120 JYJPJ85/SC 0.6/1kV 1×1.5 8.7 130 JYJPJ85/SC 0.6/1kV 1×2.5 9.2 150 JYJPJ85/SC 0.6/1kV 1×4.0 9.7 173 JYJPJ85/SC 0.6/1kV 1×6.0 10.2 203 JYJPJ85/SC 0.6/1kV 1×10 11.2 259 JYJPJ85/SC 0.6/1kV 1×16 12.8 352 JYJPJ85/SC 0.6/1kV 1×25 14.5 475 JYJPJ85/SC 0.6/1kV 1×35 15.9 601 JYJPJ85/SC 0.6/1kV 1×50 18.3 816 JYJPJ85/SC 0.6/1kV 1×70 20.0 1027 JYJPJ85/SC 0.6/1kV 1×95 22.3 1321 JYJPJ85/SC 0.6/1kV 1×120 24.4 1634 JYJPJ85/SC 0.6/1kV 1×150 26.9 1972 JYJPJ85/SC 0.6/1kV 1×185 29.2 2351 JYJPJ85/SC 0.6/1kV 1×240 32.4 2981 JYJPJ85/SC 0.6/1kV 1×300 35.5 3668 JYJPJ85/SC 0.6/1kV 2×1.0 11.7 216 JYJPJ85/SC 0.6/1kV 2×1.5 12.7 254 JYJPJ85/SC 0.6/1kV 2×2.5 13.7 302 JYJPJ85/SC 0.6/1kV 2×4.0 14.7 360 JYJPJ85/SC 0.6/1kV 2×6.0 16.1 442 JYJPJ85/SC 0.6/1kV 2×10 18.4 601 JYJPJ85/SC 0.6/1kV 2×16 21.2 824 JYJPJ85/SC 0.6/1kV 2×25 25.1 1170 JYJPJ85/SC 0.6/1kV 2×35 27.7 1481 JYJPJ85/SC 0.6/1kV 2×50 31.9 2018 JYJPJ85/SC 0.6/1kV 2×70 36.1 2615 JYJPJ85/SC 0.6/1kV 2×95 40.2 3344 JYJPJ85/SC 0.6/1kV 2×120 44.7 4185 JYJPJ85/SC 0.6/1kV 3×1.0 12.6 249 JYJPJ85/SC 0.6/1kV 3×1.5 13.2 278 JYJPJ85/SC 0.6/1kV 3×2.5 14.2 337 JYJPJ85/SC 0.6/1kV 3×4.0 15.6 418 JYJPJ85/SC 0.6/1kV 3×6.0 17.0 519 JYJPJ85/SC 0.6/1kV 3×10 19.3 707 JYJPJ85/SC 0.6/1kV 3×16 22.2 986 JYJPJ85/SC 0.6/1kV 3×25 26.4 1418 JYJPJ85/SC 0.6/1kV 3×35 29.7 1848 JYJPJ85/SC 0.6/1kV 3×50 34.2 2539 JYJPJ85/SC 0.6/1kV 3×70 38.6 3304 JYJPJ85/SC 0.6/1kV 3×95 43.0 4257 JYJPJ85/SC 0.6/1kV 3×120 48.9 5418 JYJPJ85/SC 0.6/1kV 3×150 52.5 6466 JYJPJ85/SC 0.6/1kV 3×185 57.6 7801 JYJPJ85/SC 0.6/1kV 4×1.0 13.4 279 JYJPJ85/SC 0.6/1kV 4×1.5 14.0 315 JYJPJ85/SC 0.6/1kV 4×2.5 15.4 397 JYJPJ85/SC 0.6/1kV 4×4.0 16.9 496 JYJPJ85/SC 0.6/1kV 4×6.0 18.5 623 JYJPJ85/SC 0.6/1kV 4×10 21.2 870 JYJPJ85/SC 0.6/1kV 4×16 24.3 1208 JYJPJ85/SC 0.6/1kV 4×25 28.8 1750 JYJPJ85/SC 0.6/1kV 4×35 32.5 2291 JYJPJ85/SC 0.6/1kV 4×50 37.7 3188 JYJPJ85/SC 0.6/1kV 4×70 42.6 4159 JYJPJ85/SC 0.6/1kV 4×95 47.6 5401 JYJPJ85/SC 0.6/1kV 4×120 53.0 6790 JYJPJ85/SC 0.6/1kV 4×150 58.1 8222 JYJPJ85/SC 0.6/1kV 5×1 14.2 315 JYJPJ85/SC 0.6/1kV 6×1 15.3 362 JYJPJ85/SC 0.6/1kV 7×1 15.3 362 JYJPJ85/SC 0.6/1kV 8×1 16.4 403 JYJPJ85/SC 0.6/1kV 10×1 18.7 495 JYJPJ85/SC 0.6/1kV 12×1 19.1 530 JYJPJ85/SC 0.6/1kV 14×1 19.9 576 JYJPJ85/SC 0.6/1kV 16×1 21.2 650 JYJPJ85/SC 0.6/1kV 19×1 22.1 705 JYJPJ85/SC 0.6/1kV 24×1 25.4 877 JYJPJ85/SC 0.6/1kV 27×1 25.9 928 JYJPJ85/SC 0.6/1kV 30×1 26.9 1004 JYJPJ85/SC 0.6/1kV 33×1 27.7 1071 JYJPJ85/SC 0.6/1kV 37×1 28.6 1142 JYJPJ85/SC 0.6/1kV 5×1.5 15.2 367 JYJPJ85/SC 0.6/1kV 6×1.5 16.1 413 JYJPJ85/SC 0.6/1kV 7×1.5 16.1 416 JYJPJ85/SC 0.6/1kV 8×1.5 17.3 464 JYJPJ85/SC 0.6/1kV 10×1.5 19.8 572 JYJPJ85/SC 0.6/1kV 12×1.5 20.2 618 JYJPJ85/SC 0.6/1kV 14×1.5 21.5 699 JYJPJ85/SC 0.6/1kV 16×1.5 22.5 762 JYJPJ85/SC 0.6/1kV 19×1.5 23.4 833 JYJPJ85/SC 0.6/1kV 24×1.5 27.3 1054 JYJPJ85/SC 0.6/1kV 27×1.5 27.8 1120 JYJPJ85/SC 0.6/1kV 30×1.5 28.6 1199 JYJPJ85/SC 0.6/1kV 33×1.5 30.0 1315 JYJPJ85/SC 0.6/1kV 37×1.5 30.9 1407 JYJPJ85/SC 0.6/1kV 5×2.5 16.7 464 JYJPJ85/SC 0.6/1kV 6×2.5 18.0 538 JYJPJ85/SC 0.6/1kV 7×2.5 18.0 546 JYJPJ85/SC 0.6/1kV 8×2.5 19.1 600 JYJPJ85/SC 0.6/1kV 10×2.5 22.2 755 JYJPJ85/SC 0.6/1kV 12×2.5 22.7 822 JYJPJ85/SC 0.6/1kV 14×2.5 23.9 919 JYJPJ85/SC 0.6/1kV 16×2.5 25.2 1023 JYJPJ85/SC 0.6/1kV 19×2.5 26.3 1127 JYJPJ85/SC 0.6/1kV 24×2.5 30.6 1425 JYJPJ85/SC 0.6/1kV 27×2.5 31.2 1525 JYJPJ85/SC 0.6/1kV 30×2.5 32.1 1641 JYJPJ85/SC 0.6/1kV 33×2.5 33.7 1799 JYJPJ85/SC 0.6/1kV 37×2.5 34.8 1936 JYJPJ85/SC 0.6/1kV 5×4.0 18.3 584 JYJPJ85/SC 0.6/1kV 6×4.0 19.6 669 JYJPJ85/SC 0.6/1kV 7×4.0 19.6 685 JYJPJ85/SC 0.6/1kV 8×4.0 21.3 779 JYJPJ85/SC 0.6/1kV 10×4.0 24.4 968 JYJPJ85/SC 0.6/1kV 12×4.0 25.3 1078 JYJPJ85/SC 0.6/1kV 14×4.0 26.4 1195 JYJPJ85/SC 0.6/1kV 16×4.0 27.8 1335 JYJPJ85/SC 0.6/1kV 19×4.0 29.3 1498 JYJPJ85/SC 0.6/1kV 24×4.0 34.2 1893 JYJPJ85/SC 0.6/1kV 27×4.0 34.8 2037 JYJPJ85/SC 0.6/1kV 30×4.0 36.1 2219 JYJPJ85/SC 0.6/1kV 33×4.0 37.3 2392 JYJPJ85/SC 0.6/1kV 37×4.0 39.1 2627
Key words:
Power cable for ships with rated voltage of 0.6/1kv
Product inquiry
Filling in your phone and E-mail information will help us to get in touch with you in time and solve your problems as soon as possible.
Jiangsu Zhongmei Cable Co., Ltd.
National Service Hotline:0510-87201409
Company fax: 0510-87219001
Enterprise E-mail:web@jszmkl.com
Company address:No. 6, Shuguang Road, Guanlin Town, Yixing City, Jiangsu Province
Focus on us
Visit mobile official website