Build a centenary enterprise, Forge an international brand

Products

Shield monitoring reinforced flexible cable for Shearer


Summary:

Mcpjb-0.66/1.14 and mcpjr-0.66/1.14 are applicable to the power connection of shearer and similar equipment with rated voltage of 0.66/1.14kv and below, and the cable can be directly dragged for use.
  • Product Description
  • Parameter
  • 1. Product executive standard

    MT 818-2009。

    2. Product application scope

    Mcpjb-0.66/1.14 and mcpjr-0.66/1.14 are applicable to the power connection of shearer and similar equipment with rated voltage of 0.66/1.14kv and below, and the cable can be directly dragged for use.

    Mcpjb-1.9 / 3.3 and mcpjr-1.9 / 3.3 are applicable to the power connection of shearer and similar equipment with rated voltage of 1.9/3.3kv and below, and the cable can be directly dragged for use.

    3. Product use characteristics

    3.1. Rated voltage: 0.66/1.14kv, 1.9/3.3kv.

    3.2. The maximum allowable working temperature of conductor is 90 ℃, and the maximum temperature of conductor in case of short circuit (the short circuit time shall not exceed 5S) is 250 ℃.

    3.3. The minimum bending radius of cable is 6 times of cable diameter.

    3.4. The normal applicable ambient temperature of the cable is - 25 ℃ ~ + 65 ℃.

    3.5. The flame retardant performance of the cable shall meet the requirements of flame retardant performance in MT 818-2009.

    3.6 power frequency withstand voltage of cable: 0.66/1.14kv voltage: 3.7kv/5min without breakdown, 1.9/3kv voltage: 6.8kv/5min without breakdown.

    4. Main technical indexes of cable

    4.1. Conductor structure: Tinned Soft Copper conductor, in accordance with GB / T 3956, type 5 soft copper conductor.

    4.2. Insulating material: the power core and control core are made of EPDM based insulating rubber, whose performance shall conform to the requirements of xj-30a type in GB / T 7594.8, and the tensile strength shall not be less than 6.5MPa.

    4.3. Core identification: main core: code or color yarn identification; control line: white insulation plus black code.

    4.4. Outer sheath: the sheath rubber or other materials with similar performance based on chlorinated polyethylene rubber shall meet the requirements of xh-21 type in GB / T 7594.9, and the tear strength shall not be less than 5.0n/mm.

  • Model Voltage Specifications Reference OD Reference weight
    MCPJR 0.66/1.14KV 3*35+1*16+3*1.5+3*1.5 42.4  3168 
    MCPJR 0.66/1.14KV 3*50+1*25+3*1.5+3*1.5 48.3  4114 
    MCPJR 0.66/1.14KV 3*70+1*35+3*1.5+3*1.5 52.9  5042 
    MCPJR 0.66/1.14KV 3*95+1*50+3*1.5+3*1.5 59.5  6295 
    MCPJB 0.66/1.14KV 3*35+1*16+3*1.5+3*1.5 45.3  3249 
    MCPJB 0.66/1.14KV 3*50+1*25+3*1.5+3*1.5 51.4  4188 
    MCPJB 0.66/1.14KV 3*70+1*35+3*1.5+3*1.5 56.1  4954 
    MCPJB 0.66/1.14KV 3*95+1*50+3*1.5+3*1.5 62.6  6342 
    MCPJR 1.9/3.3KV 3*35+1*16+3*1.5+3*1.5 48.0  3772 
    MCPJR 1.9/3.3KV 3*50+1*25+3*1.5+3*1.5 53.4  4764 
    MCPJR 1.9/3.3KV 3*70+1*35+3*1.5+3*1.5 58.0  5900 
    MCPJR 1.9/3.3KV 3*95+1*50+3*1.5+3*1.5 63.8  7047 
    MCPJB 1.9/3.3KV 3*35+1*16+3*1.5+3*1.5 51.3  3826 
    MCPJB 1.9/3.3KV 3*50+1*25+3*1.5+3*1.5 56.5  4863 
    MCPJB 1.9/3.3KV 3*70+1*35+3*1.5+3*1.5 61.5  5713 
    MCPJB 1.9/3.3KV 3*95+1*50+3*1.5+3*1.5 66.7  7094 

     

Key words:

Shield monitoring reinforced flexible cable for Shearer

Product inquiry

Filling in your phone and E-mail information will help us to get in touch with you in time and solve your problems as soon as possible.

Jiangsu Zhongmei Cable Co., Ltd.

National Service Hotline:0510-87201409

Company fax: 0510-87219001

Enterprise E-mail:web@jszmkl.com

Company address:No. 6, Shuguang Road, Guanlin Town, Yixing City, Jiangsu Province

Focus on us

Visit mobile official website

Visit mobile official website

©2024 Jiangsu Zhongmei Cable Co., Ltd.

Business License