Marine power cable with rated voltage of 0.6/1kv


Summary:

Marine power cable can be used for power lighting and general control devices of various ships and offshore oil platforms. It is also applicable to metallurgical, chemical, electric and other industrial and mining enterprises.
  • Product Description
  • Parameter
  • 1. Product executive standard

    IEC 60092-350、IEC 60092-353。

    2. Product application:

    Marine power cable can be used for power lighting and general control devices of various ships and offshore oil platforms. It is also applicable to metallurgical, chemical, electric and other industrial and mining enterprises.

    3. Product use characteristics

    3.1. Rated voltage: 0.6/1kv.

    3.2. The maximum allowable working temperature of conductor is 90 ℃, and the maximum temperature of conductor in case of short circuit (the short circuit time shall not exceed 5S) is 250 ℃.

    3.3. Minimum bending radius of cable installation: 6D.

    3.4. Ambient temperature of cable installation: - Ge; 0 ℃; ambient temperature of cable use: - 15 ℃ ~ 70 ℃.

    3.5 power frequency withstand voltage of cable: 3.5kv/5min, no breakdown.

    4. Main technical indexes of cable

    4.1. Conductor structure: tinned copper wire, conforming to the second type of stranded conductor in GB / T 3956.

    4.2. Insulation material: cross linked polyethylene, in accordance with the relevant requirements of IEC 60092-360.

    4.3. Core identification: white insulation black digital code.

    4.4. Sheath: low smoke, halogen-free, non crosslinked polyolefin, meeting the relevant requirements of IEC 60092-360.

  • Model Voltage Specifications Reference outer diameter mm Reference weight kg / km
    CJPF/SC 0.6/1kV 1*1 5.7  40
    CJPF/SC 0.6/1kV 1*1.5 6.0  47
    CJPF/SC 0.6/1kV 1*2.5 6.4  61
    CJPF/SC 0.6/1kV 1*4 6.9  78
    CJPF/SC 0.6/1kV 1*6 7.5  100
    CJPF/SC 0.6/1kV 1*10 8.4  145
    CJPF/SC 0.6/1kV 1*16 9.6  211
    CJPF/SC 0.6/1kV 1*25 11.3  320
    CJPF/SC 0.6/1kV 1*35 12.7  422
    CJPF/SC 0.6/1kV 1*50 14.4  558
    CJPF/SC 0.6/1kV 1*70 16.4  775
    CJPF/SC 0.6/1kV 1*95 18.5  1045
    CJPF/SC 0.6/1kV 1*120 20.6  1304
    CJPF/SC 0.6/1kV 1*150 22.7  1599
    CJPF/SC 0.6/1kV 1*185 25.0  1994
    CJPF/SC 0.6/1kV 1*240 28.2  2577
    CJPF/SC 0.6/1kV 1*300 31.0  3200
    CJPF/SC 0.6/1kV 2*1 8.8  92
    CJPF/SC 0.6/1kV 2*1.5 9.6  114
    CJPF/SC 0.6/1kV 2*2.5 10.4  149
    CJPF/SC 0.6/1kV 2*4 11.4  194
    CJPF/SC 0.6/1kV 2*6 12.8  259
    CJPF/SC 0.6/1kV 2*10 14.8  381
    CJPF/SC 0.6/1kV 2*16 16.8  549
    CJPF/SC 0.6/1kV 2*25 20.8  840
    CJPF/SC 0.6/1kV 2*35 23.4  1115
    CJPF/SC 0.6/1kV 2*50 26.6  1472
    CJPF/SC 0.6/1kV 2*70 31.0  2070
    CJPF/SC 0.6/1kV 2*95 35.0  2759
    CJPF/SC 0.6/1kV 2*120 38.6  3457
    CJPF/SC 0.6/1kV 3*1 9.5  109
    CJPF/SC 0.6/1kV 3*1.5 10.1  131
    CJPF/SC 0.6/1kV 3*2.5 11.0  176
    CJPF/SC 0.6/1kV 3*4 12.3  240
    CJPF/SC 0.6/1kV 3*6 13.6  316
    CJPF/SC 0.6/1kV 3*10 15.7  475
    CJPF/SC 0.6/1kV 3*16 18.0  694
    CJPF/SC 0.6/1kV 3*25 22.1  1069
    CJPF/SC 0.6/1kV 3*35 24.9  1429
    CJPF/SC 0.6/1kV 3*50 28.5  1909
    CJPF/SC 0.6/1kV 3*70 33.0  2695
    CJPF/SC 0.6/1kV 3*95 37.5  3614
    CJPF/SC 0.6/1kV 3*120 41.4  4530
    CJPF/SC 0.6/1kV 3*150 45.9  5557
    CJPF/SC 0.6/1kV 3*185 51.4  6961
    CJPF/SC 0.6/1kV 4*1 10.3  130
    CJPF/SC 0.6/1kV 5*1 11.2  153
    CJPF/SC 0.6/1kV 7*1 12.3  186
    CJPF/SC 0.6/1kV 10*1 15.6  268
    CJPF/SC 0.6/1kV 12*1 16.1  297
    CJPF/SC 0.6/1kV 14*1 16.9  332
    CJPF/SC 0.6/1kV 16*1 17.8  379
    CJPF/SC 0.6/1kV 19*1 18.9  421
    CJPF/SC 0.6/1kV 24*1 22.4  534
    CJPF/SC 0.6/1kV 27*1 22.9  577
    CJPF/SC 0.6/1kV 30*1 23.7  627
    CJPF/SC 0.6/1kV 33*1 24.8  692
    CJPF/SC 0.6/1kV 37*1 25.7  748
    CJPF/SC 0.6/1kV 4*1.5 11.0  157
    CJPF/SC 0.6/1kV 5*1.5 12.2  193
    CJPF/SC 0.6/1kV 7*1.5 13.2  229
    CJPF/SC 0.6/1kV 10*1.5 16.8  331
    CJPF/SC 0.6/1kV 12*1.5 17.3  369
    CJPF/SC 0.6/1kV 14*1.5 18.4  424
    CJPF/SC 0.6/1kV 16*1.5 19.4  474
    CJPF/SC 0.6/1kV 19*1.5 20.4  530
    CJPF/SC 0.6/1kV 24*1.5 24.4  684
    CJPF/SC 0.6/1kV 27*1.5 24.9  742
    CJPF/SC 0.6/1kV 30*1.5 25.8  808
    CJPF/SC 0.6/1kV 33*1.5 26.8  878
    CJPF/SC 0.6/1kV 37*1.5 28.0  966
    CJPF/SC 0.6/1kV 4*2.5 12.2  220
    CJPF/SC 0.6/1kV 5*2.5 13.3  264
    CJPF/SC 0.6/1kV 7*2.5 14.4  328
    CJPF/SC 0.6/1kV 10*2.5 18.6  473
    CJPF/SC 0.6/1kV 12*2.5 19.2  532
    CJPF/SC 0.6/1kV 14*2.5 20.2  612
    CJPF/SC 0.6/1kV 16*2.5 21.7  687
    CJPF/SC 0.6/1kV 19*2.5 22.8  774
    CJPF/SC 0.6/1kV 24*2.5 27.0  994
    CJPF/SC 0.6/1kV 27*2.5 27.6  1085
    CJPF/SC 0.6/1kV 30*2.5 28.6  1185
    CJPF/SC 0.6/1kV 33*2.5 29.9  1305
    CJPF/SC 0.6/1kV 37*2.5 31.0  1423

Key words:

Marine power cable with rated voltage of 0.6/1kv

Product inquiry

Filling in your phone and E-mail information will help us to get in touch with you in time and solve your problems as soon as possible.

Jiangsu Zhongmei Cable Co., Ltd.

National Service Hotline:0510-87201409

Company fax: 0510-87219001

Enterprise E-mail:web@jszmkl.com

Company address:No. 6, Shuguang Road, Guanlin Town, Yixing City, Jiangsu Province

Focus on us

Visit mobile official website

Visit mobile official website

©2024 Jiangsu Zhongmei Cable Co., Ltd.

Business License