Build a centenary enterprise, Forge an international brand

Products

Marine power cable with rated voltage of 0.6/1kv


Summary:

Marine power cable can be used for power lighting and general control devices of various ships and offshore oil platforms. It is also applicable to metallurgical, chemical, electric and other industrial and mining enterprises.
  • Product Description
  • Parameter
  • 1. Product executive standard

    IEC 60092-350、IEC 60092-353。

    2. Product application scope

    Marine power cable can be used for power lighting and general control devices of various ships and offshore oil platforms. It is also applicable to metallurgical, chemical, electric and other industrial and mining enterprises.

    3. Product use characteristics

    3.1. Rated voltage: 0.6/1kv.

    3.2. The maximum allowable working temperature of conductor is 90 ℃, and the maximum temperature of conductor in case of short circuit (the short circuit time shall not exceed 5S) is 250 ℃.

    3.3. Minimum bending radius of cable installation: 6D.

    3.4. Ambient temperature of cable installation: - Ge; 0 ℃; ambient temperature of cable use: - 15 ℃ ~ 70 ℃.

    3.5 power frequency withstand voltage of cable: 3.5kv/5min, no breakdown.

    4. Main technical indexes of cable

    4.1. Conductor structure: tinned copper wire, conforming to the second type of stranded conductor in GB / T 3956.

    4.2. Insulation material: cross linked polyethylene, in accordance with the relevant requirements of IEC 60092-360.

    4.3. Core identification: white insulation black digital code.

    4.4. Sheath: PVC, in accordance with the relevant requirements of IEC 60092-360.

  • Model Voltage Specifications Reference outer diameter mm Reference weight kg / km
    CJV/SA 0.6/1kV 1*1 5.7 40
    CJV/SA 0.6/1kV 1*1.5 6 47
    CJV/SA 0.6/1kV 1*2.5 6.4 61
    CJV/SA 0.6/1kV 1*4 6.9 78
    CJV/SA 0.6/1kV 1*6 7.5 100
    CJV/SA 0.6/1kV 1*10 8.4 145
    CJV/SA 0.6/1kV 1*16 9.6 211
    CJV/SA 0.6/1kV 1*25 11.3 320
    CJV/SA 0.6/1kV 1*35 12.7 422
    CJV/SA 0.6/1kV 1*50 14.4 558
    CJV/SA 0.6/1kV 1*70 16.4 775
    CJV/SA 0.6/1kV 1*95 18.5 1045
    CJV/SA 0.6/1kV 1*120 20.6 1304
    CJV/SA 0.6/1kV 1*150 22.7 1599
    CJV/SA 0.6/1kV 1*185 25 1994
    CJV/SA 0.6/1kV 1*240 28.2 2577
    CJV/SA 0.6/1kV 1*300 31 3200
    CJV/SA 0.6/1kV 2*1 8.8 92
    CJV/SA 0.6/1kV 2*1.5 9.6 114
    CJV/SA 0.6/1kV 2*2.5 10.4 149
    CJV/SA 0.6/1kV 2*4 11.4 194
    CJV/SA 0.6/1kV 2*6 12.8 259
    CJV/SA 0.6/1kV 2*10 14.8 381
    CJV/SA 0.6/1kV 2*16 16.8 549
    CJV/SA 0.6/1kV 2*25 20.8 840
    CJV/SA 0.6/1kV 2*35 23.4 1115
    CJV/SA 0.6/1kV 2*50 26.6 1472
    CJV/SA 0.6/1kV 2*70 31 2070
    CJV/SA 0.6/1kV 2*95 35 2759
    CJV/SA 0.6/1kV 2*120 38.6 3457
    CJV/SA 0.6/1kV 3*1 9.5 109
    CJV/SA 0.6/1kV 3*1.5 10.1 131
    CJV/SA 0.6/1kV 3*2.5 11 176
    CJV/SA 0.6/1kV 3*4 12.3 240
    CJV/SA 0.6/1kV 3*6 13.6 316
    CJV/SA 0.6/1kV 3*10 15.7 475
    CJV/SA 0.6/1kV 3*16 18 694
    CJV/SA 0.6/1kV 3*25 22.1 1069
    CJV/SA 0.6/1kV 3*35 24.9 1429
    CJV/SA 0.6/1kV 3*50 28.5 1909
    CJV/SA 0.6/1kV 3*70 33 2695
    CJV/SA 0.6/1kV 3*95 37.5 3614
    CJV/SA 0.6/1kV 3*120 41.4 4530
    CJV/SA 0.6/1kV 3*150 45.9 5557
    CJV/SA 0.6/1kV 3*185 51.4 6961
    CJV/SA 0.6/1kV 4*1 10.3 130
    CJV/SA 0.6/1kV 5*1 11.2 153
    CJV/SA 0.6/1kV 7*1 12.3 186
    CJV/SA 0.6/1kV 10*1 15.6 268
    CJV/SA 0.6/1kV 12*1 16.1 297
    CJV/SA 0.6/1kV 14*1 16.9 332
    CJV/SA 0.6/1kV 16*1 17.8 379
    CJV/SA 0.6/1kV 19*1 18.9 421
    CJV/SA 0.6/1kV 24*1 22.4 534
    CJV/SA 0.6/1kV 27*1 22.9 577
    CJV/SA 0.6/1kV 30*1 23.7 627
    CJV/SA 0.6/1kV 33*1 24.8 692
    CJV/SA 0.6/1kV 37*1 25.7 748
    CJV/SA 0.6/1kV 4*1.5 11 157
    CJV/SA 0.6/1kV 5*1.5 12.2 193
    CJV/SA 0.6/1kV 7*1.5 13.2 229
    CJV/SA 0.6/1kV 10*1.5 16.8 331
    CJV/SA 0.6/1kV 12*1.5 17.3 369
    CJV/SA 0.6/1kV 14*1.5 18.4 424
    CJV/SA 0.6/1kV 16*1.5 19.4 474
    CJV/SA 0.6/1kV 19*1.5 20.4 530
    CJV/SA 0.6/1kV 24*1.5 24.4 684
    CJV/SA 0.6/1kV 27*1.5 24.9 742
    CJV/SA 0.6/1kV 30*1.5 25.8 808
    CJV/SA 0.6/1kV 33*1.5 26.8 878
    CJV/SA 0.6/1kV 37*1.5 28 966
    CJV/SA 0.6/1kV 4*2.5 12.2 220
    CJV/SA 0.6/1kV 5*2.5 13.3 264
    CJV/SA 0.6/1kV 7*2.5 14.4 328
    CJV/SA 0.6/1kV 10*2.5 18.6 473
    CJV/SA 0.6/1kV 12*2.5 19.2 532
    CJV/SA 0.6/1kV 14*2.5 20.2 612
    CJV/SA 0.6/1kV 16*2.5 21.7 687
    CJV/SA 0.6/1kV 19*2.5 22.8 774
    CJV/SA 0.6/1kV 24*2.5 27 994
    CJV/SA 0.6/1kV 27*2.5 27.6 1085
    CJV/SA 0.6/1kV 30*2.5 28.6 1185
    CJV/SA 0.6/1kV 33*2.5 29.9 1305
    CJV/SA 0.6/1kV 37*2.5 31 1423

Key words:

Marine power cable with rated voltage of 0.6/1kv

Product inquiry

Filling in your phone and E-mail information will help us to get in touch with you in time and solve your problems as soon as possible.

Jiangsu Zhongmei Cable Co., Ltd.

National Service Hotline:0510-87201409

Company fax: 0510-87219001

Enterprise E-mail:web@jszmkl.com

Company address:No. 6, Shuguang Road, Guanlin Town, Yixing City, Jiangsu Province

Focus on us

Visit mobile official website

Visit mobile official website

©2024 Jiangsu Zhongmei Cable Co., Ltd.

Business License