Communication cable for ships with rated voltage of 300V

  • Product description
  • Parameter

1. Product executive standard

GJB 1916-94, enterprise standard.

2. Product application scope

Shipboard communication cable is mainly used in various shipboard and shipboard telecommunications, electronic computers, information processing equipment in the signal and control system.

3. Product use characteristics

3.1. Rated voltage: 300V.

3.2. The maximum allowable working temperature of conductor is 90 ℃, and the maximum temperature of conductor in case of short circuit (the short circuit time shall not exceed 5S) is 250 ℃.

3.3. Minimum bending radius of cable installation: 6D.

3.4. Ambient temperature of cable installation: - Ge; 0 ℃; ambient temperature of cable use: - 15 ℃ ~ 70 ℃.

3.5 power frequency withstand voltage of cable: 1.5kv/5min, no breakdown.

4. Main technical indexes of cable

4.1. Conductor structure: tinned copper wire, conforming to GJB 1916-94 Table 1-1 conductor.

4.2. Fire resistance: mica tape.

4.3. Insulation material: XLPE.

4.4. Core identification: white and blue insulation digital code.

4.5. Split screen: tinned copper wire.

4.6. Armor: tinned copper wire.

4.7. Sheath: low smoke halogen-free crosslinked polyolefin.

Model Voltage Specifications Reference outer diameter mm Reference weight kg / km
JHYJP85/NSC 300V 1×2×0.35 9.5  137 
JHYJP85/NSC 300V 2×2×0.35 13.9  234 
JHYJP85/NSC 300V 3×2×0.35 14.8  278 
JHYJP85/NSC 300V 4×2×0.35 16.0  324 
JHYJP85/NSC 300V 5×2×0.35 17.6  380 
JHYJP85/NSC 300V 7×2×0.35 18.9  454 
JHYJP85/NSC 300V 10×2×0.35 24.0  635 
JHYJP85/NSC 300V 12×2×0.35 24.7  698 
JHYJP85/NSC 300V 14×2×0.35 26.1  783 
JHYJP85/NSC 300V 16×2×0.35 27.5  858 
JHYJP85/NSC 300V 19×2×0.35 29.1  975 
JHYJP85/NSC 300V 24×2×0.35 34.1  1226 
JHYJP85/NSC 300V 27×2×0.35 34.8  1315 
JHYJP85/NSC 300V 30×2×0.35 36.0  1415 
JHYJP85/NSC 300V 33×2×0.35 37.6  1537 
JHYJP85/NSC 300V 37×2×0.35 39.2  1687 
JHYJP85/NSC 300V 44×2×0.35 44.0  1985 
JHYJP85/NSC 300V 48×2×0.35 45.0  2124 
JHYJP85/NSC 300V 1×2×0.5 9.9  147
JHYJP85/NSC 300V 2×2×0.5 14.7  262
JHYJP85/NSC 300V 3×2×0.5 15.5  305
JHYJP85/NSC 300V 4×2×0.5 16.8  356
JHYJP85/NSC 300V 5×2×0.5 18.4  420
JHYJP85/NSC 300V 7×2×0.5 20.1  516
JHYJP85/NSC 300V 10×2×0.5 25.5  722
JHYJP85/NSC 300V 12×2×0.5 26.3  796
JHYJP85/NSC 300V 14×2×0.5 27.6  880
JHYJP85/NSC 300V 16×2×0.5 29.2  982
JHYJP85/NSC 300V 19×2×0.5 30.9  1117
JHYJP85/NSC 300V 24×2×0.5 36.3  1404
JHYJP85/NSC 300V 27×2×0.5 37.1  1509
JHYJP85/NSC 300V 30×2×0.5 38.4  1626
JHYJP85/NSC 300V 33×2×0.5 4