zhomei
Search
Search

Power cable for ships with rated voltage of 0.6/1kv

  • Product description
  • Parameter

1. Product executive standard

GJB 1916-94, enterprise standard.

2. Product application scope

Power cables for ships can be used for power, lighting and general control devices of various ships and offshore oil platforms.

3. Product use characteristics

3.1. Rated voltage: 0.6/1kv.

3.2. The maximum allowable working temperature of conductor is 90 ℃, and the maximum temperature of conductor in case of short circuit (the short circuit time shall not exceed 5S) is 250 ℃.

3.3. Minimum bending radius of cable installation: 6D.

3.4. Ambient temperature of cable installation: - Ge; 0 ℃; ambient temperature of cable use: - 15 ℃ ~ 70 ℃.

3.5 power frequency withstand voltage of cable: 3.5kv/5min, no breakdown.

4. Main technical indexes of cable

4.1. Conductor structure: tinned copper wire, conforming to GJB 1916-94 Table 1-1 conductor.

4.2. Insulation material: XLPE.

4.3. Core identification: white insulation black digital code.

4.4. Sheath: low smoke halogen-free crosslinked polyolefin.

Model Voltage Specifications Reference outer diameter mm Reference weight kg / km
JYJPJ/SC 0.6/1kV 1×1.0 5.3  38
JYJPJ/SC 0.6/1kV 1×1.5 5.6  45
JYJPJ/SC 0.6/1kV 1×2.5 6.0  58
JYJPJ/SC 0.6/1kV 1×4.0 6.6  76
JYJPJ/SC 0.6/1kV 1×6.0 7.1  98
JYJPJ/SC 0.6/1kV 1×10 8.1  143
JYJPJ/SC 0.6/1kV 1×16 9.4  213
JYJPJ/SC 0.6/1kV 1×25 11.1  314
JYJPJ/SC 0.6/1kV 1×35 12.6  422
JYJPJ/SC 0.6/1kV 1×50 14.7  602
JYJPJ/SC 0.6/1kV 1×70 16.4  789
JYJPJ/SC 0.6/1kV 1×95 18.5  1046
JYJPJ/SC 0.6/1kV 1×120 20.6  1331
JYJPJ/SC 0.6/1kV 1×150 22.8  1627
JYJPJ/SC 0.6/1kV 1×185 24.8  1961
JYJPJ/SC 0.6/1kV 1×240 28.1  2548
JYJPJ/SC 0.6/1kV 1×300 31.0  3177
JYJPJ/SC 0.6/1kV 2×1.0  9.1  103
JYJPJ/SC 0.6/1kV 2×1.5  9.6  121
JYJPJ/SC 0.6/1kV 2×2.5  10.6  157
JYJPJ/SC 0.6/1kV 2×4.0  11.8  209
JYJPJ/SC 0.6/1kV 2×6.0  13.0  269
JYJPJ/SC 0.6/1kV 2×10 15.1  393
JYJPJ/SC 0.6/1kV 2×16 17.6  574
JYJPJ/SC 0.6/1kV 2×25 21.2  860
JYJPJ/SC 0.6/1kV 2×35 23.9  1137
JYJPJ/SC 0.6/1kV 2×50 28.1  1621
JYJPJ/SC 0.6/1kV 2×70 31.8  2133
JYJPJ/SC 0.6/1kV 2×95 35.6  2788
JYJPJ/SC 0.6/1kV 2×120 39.9  3548
JYJPJ/SC 0.6/1kV 3×1.0  9.3  111
JYJPJ/SC 0.6/1kV 3×1.5  9.8  133
JYJPJ/SC 0.6/1kV 3×2.5  10.9  179
JYJPJ/SC 0.6/1kV 3×4.0  12.2  243
JYJPJ/SC 0.6/1kV 3×6.0  13.4  320
JYJPJ/SC 0.6/1kV 3×10 15.7  480
JYJPJ/SC 0.6/1kV 3×16 18.4  712
JYJPJ/SC 0.6/1kV 3×25 22.3  1078
JYJPJ/SC 0.6/1kV 3×35 25.4  1453
JYJPJ/SC 0.6/1kV 3×50 29.6  2066
JYJPJ/SC 0.6/1kV 3×70 33.8  2753
JYJPJ/SC 0.6/1kV 3×95 37.9  3622
JYJPJ/SC 0.6/1kV 3×120 42.5  4619
JYJPJ/SC 0.6/1kV 3×150 47.0  5644
JYJPJ/SC 0.6/1kV 3×185 51.9  6874
JYJPJ/SC 0.6/1kV 4×1.0  10.0  133
JYJPJ/SC 0.6/1kV 4×1.5  10.7  160
JYJPJ/SC 0.6/1kV 4×2.5  12.1  225
JYJPJ/SC 0.6/1kV 4×4.0  13.3  299
JYJPJ/SC 0.6/1kV 4×6.0  14.9  405
JYJPJ/SC 0.6/1kV 4×10 17.4  610
JYJPJ/SC 0.6/1kV 4×16 20.4  908
JYJPJ/SC 0.6/1kV 4×25 24.8  1378
JYJPJ/SC 0.6/1kV 4×35 28.1  1858
JYJPJ/SC 0.6/1kV 4×50 32.9  2648
JYJPJ/SC 0.6/1kV 4×70 37.5  3531
JYJPJ/SC 0.6/1kV 4×95 42.3  4678
JYJPJ/SC 0.6/1kV 4×120 47.4  5964
JYJPJ/SC 0.6/1kV 4×150 52.4  7287
JYJPJ/SC 0.6/1kV 5×1 11.4  164
JYJPJ/SC 0.6/1kV 6×1 12.6  200
JYJPJ/SC 0.6/1kV 7×1 12.6  198
JYJPJ/SC 0.6/1kV 8×1 13.5  220
JYJPJ/SC 0.6/1kV 10×1 15.9  286
JYJPJ/SC 0.6/1kV 12×1 16.4  315
JYJPJ/SC 0.6/1kV 14×1 16.3  341
JYJPJ/SC 0.6/1kV 16×1 17.3  390
JYJPJ/SC 0.6/1kV 19×1 18.2  433
JYJPJ/SC 0.6/1kV 24×1 21.3  551
JYJPJ/SC 0.6/1kV 27×1 21.8  596
JYJPJ/SC 0.6/1kV 30×1 22.8  660
JYJPJ/SC 0.6/1kV 33×1 23.6  715
JYJPJ/SC 0.6/1kV 37×1 24.5  774
JYJPJ/SC 0.6/1kV 5×1.5 11.8  197
JYJPJ/SC 0.6/1kV 6×1.5 12.8  232
JYJPJ/SC 0.6/1kV 7×1.5 12.8  235
JYJPJ/SC 0.6/1kV 8×1.5 13.7  262
JYJPJ/SC 0.6/1kV 10×1.5 16.2  339
JYJPJ/SC 0.6/1kV 12×1.5 16.6  377
JYJPJ/SC 0.6/1kV 14×1.5 17.7  434
JYJPJ/SC 0.6/1kV 16×1.5 18.6  486
JYJPJ/SC 0.6/1kV 19×1.5 19.6  543
JYJPJ/SC 0.6/1kV 24×1.5 23.2  703
JYJPJ/SC 0.6/1kV 27×1.5 23.7  763
JYJPJ/SC 0.6/1kV 30×1.5 24.5  830
JYJPJ/SC 0.6/1kV 33×1.5 25.7  916
JYJPJ/SC 0.6/1kV 37×1.5 26.6  994
JYJPJ/SC 0.6/1kV 5×2.5 13.1  270
JYJPJ/SC 0.6/1kV 6×2.5 14.4  327
JYJPJ/SC 0.6/1kV 7×2.5 14.4  335
JYJPJ/SC 0.6/1kV 8×2.5 15.5  374
JYJPJ/SC 0.6/1kV 10×2.5 18.3  482
JYJPJ/SC 0.6/1kV 12×2.5 18.9  542
JYJPJ/SC 0.6/1kV 14×2.5 20.1  623
JYJPJ/SC 0.6/1kV 16×2.5 21.1  700
JYJPJ/SC 0.6/1kV 19×2.5 22.2  789
JYJPJ/SC 0.6/1kV 24×2.5 26.3  1016
JYJPJ/SC 0.6/1kV 27×2.5 26.9  1108
JYJPJ/SC 0.6/1kV 30×2.5 27.8  1210
JYJPJ/SC 0.6/1kV 33×2.5 29.1  1334
JYJPJ/SC 0.6/1kV 37×2.5 30.2  1454
JYJPJ/SC 0.6/1kV 5×4.0 14.7  369
JYJPJ/SC 0.6/1kV 6×4.0 16.0  438
JYJPJ/SC 0.6/1kV 7×4.0 16.0  454
JYJPJ/SC 0.6/1kV 8×4.0 17.5  518
JYJPJ/SC 0.6/1kV 10×4.0 20.6  665
JYJPJ/SC 0.6/1kV 12×4.0 21.2  753
JYJPJ/SC 0.6/1kV 14×4.0 22.3  855
JYJPJ/SC 0.6/1kV 16×4.0 23.7  977
JYJPJ/SC 0.6/1kV 19×4.0 25.0  1107
JYJPJ/SC 0.6/1kV 24×4.0 29.6  1420
JYJPJ/SC 0.6/1kV 27×4.0 30.3  1555
JYJPJ/SC 0.6/1kV 30×4.0 31.6  1720
JYJPJ/SC 0.6/1kV 33×4.0 32.8  1875
JYJPJ/SC 0.6/1kV 37×4.0 34.3  2070
中煤电缆

Service Hotline

中煤电缆

Company Fax

+86-0510—87219001
中煤电缆

Enterprise Email

中煤电缆

Company Address

Industrial Zone C, Guanlin Town, Yixing, Jiangsu

Seek common development

create brilliance together!

Copyright ©China Coal Technology    SupportI PV6   Powerd by:www.300.cn Changhou   备案号: 苏ICP备17026010号-1