zhomei
Search
Search

Shield monitoring reinforced flexible cable for Shearer

  • Product description
  • Parameter

1. Product executive standard

MT 818-2009。

2. Product application scope

Mcpjb-0.66/1.14 and mcpjr-0.66/1.14 are applicable to the power connection of shearer and similar equipment with rated voltage of 0.66/1.14kv and below, and the cable can be directly dragged for use.

Mcpjb-1.9 / 3.3 and mcpjr-1.9 / 3.3 are applicable to the power connection of shearer and similar equipment with rated voltage of 1.9/3.3kv and below, and the cable can be directly dragged for use.

3. Product use characteristics

3.1. Rated voltage: 0.66/1.14kv, 1.9/3.3kv.

3.2. The maximum allowable working temperature of conductor is 90 ℃, and the maximum temperature of conductor in case of short circuit (the short circuit time shall not exceed 5S) is 250 ℃.

3.3. The minimum bending radius of cable is 6 times of cable diameter.

3.4. The normal applicable ambient temperature of the cable is - 25 ℃ ~ + 65 ℃.

3.5. The flame retardant performance of the cable shall meet the requirements of flame retardant performance in MT 818-2009.

3.6 power frequency withstand voltage of cable: 0.66/1.14kv voltage: 3.7kv/5min without breakdown, 1.9/3kv voltage: 6.8kv/5min without breakdown.

4. Main technical indexes of cable

4.1. Conductor structure: Tinned Soft Copper conductor, in accordance with GB / T 3956, type 5 soft copper conductor.

4.2. Insulating material: the power core and control core are made of EPDM based insulating rubber, whose performance shall conform to the requirements of xj-30a type in GB / T 7594.8, and the tensile strength shall not be less than 6.5MPa.

4.3. Core identification: main core: code or color yarn identification; control line: white insulation plus black code.

4.4. Outer sheath: the sheath rubber or other materials with similar performance based on chlorinated polyethylene rubber shall meet the requirements of xh-21 type in GB / T 7594.9, and the tear strength shall not be less than 5.0n/mm.

Model Voltage Specifications Reference OD Reference weight
MCPJR 0.66/1.14KV 3*35+1*16+3*1.5+3*1.5 42.4  3168 
MCPJR 0.66/1.14KV 3*50+1*25+3*1.5+3*1.5 48.3  4114 
MCPJR 0.66/1.14KV 3*70+1*35+3*1.5+3*1.5 52.9  5042 
MCPJR 0.66/1.14KV 3*95+1*50+3*1.5+3*1.5 59.5  6295 
MCPJB 0.66/1.14KV 3*35+1*16+3*1.5+3*1.5 45.3  3249 
MCPJB 0.66/1.14KV 3*50+1*25+3*1.5+3*1.5 51.4  4188 
MCPJB 0.66/1.14KV 3*70+1*35+3*1.5+3*1.5 56.1  4954 
MCPJB 0.66/1.14KV 3*95+1*50+3*1.5+3*1.5 62.6  6342 
MCPJR 1.9/3.3KV 3*35+1*16+3*1.5+3*1.5 48.0  3772 
MCPJR 1.9/3.3KV 3*50+1*25+3*1.5+3*1.5 53.4  4764 
MCPJR 1.9/3.3KV 3*70+1*35+3*1.5+3*1.5 58.0  5900 
MCPJR 1.9/3.3KV 3*95+1*50+3*1.5+3*1.5 63.8  7047 
MCPJB 1.9/3.3KV 3*35+1*16+3*1.5+3*1.5 51.3  3826 
MCPJB 1.9/3.3KV 3*50+1*25+3*1.5+3*1.5 56.5  4863 
MCPJB 1.9/3.3KV 3*70+1*35+3*1.5+3*1.5 61.5  5713 
MCPJB 1.9/3.3KV 3*95+1*50+3*1.5+3*1.5 66.7  7094 

 